Configuring the Noise Floor
Even when the sensor is in a silent environment, a small level of noise is detected. You need to measure this level of noise so that the sensor ignores it when operating, otherwise it could have effects on the echogram.
Before you begin
About this task
It is recommended to measure the noise floor in water.
Procedure
- From Mosa2, click and enter the password copernic.
-
Click the tab Trawl Explorer.
-
From Noise Floor Level
Down click
Run Measure.
The noise floor average, max and min measures are displayed. -
In Noise floor
voltage:
- For a Door Sounder V1, enter the average
measure.
- For a Door Sounder with target strength
calibration, enter the recommended value next to the max. measure.
- For a Door Sounder V1, enter the average
measure.
-
Click
Apply and make sure there is a green check mark
.