Replacing the Pull Cords
You can replace the catch pull cords when they are worn out or damaged.
Before you begin
Note: Only qualified Marport technicians can
do this task.
For this task you need the following tools:
|
|
9/64" Allen key | Anti-seize |
Procedure
- Remove the old pull cords.
- Remove the four screws on the pull cord assembly with a 9/64 size Allen key.
- Remove the cords, spring and magnet from the hole.
- Install the new pull cords.
- Install the new pull-cord assembly on the side or on the end cap of the sensor.
- Apply anti-seize on the four screw threads, then tighten the screws with the 9/64 size Allen key.