Charging the Sensor

Charge the sensor at any battery level with either Marport Dock charger, Basic Sensor Charger or Medusa II Multi-charger.

About this task

The sensor uses lithium-ion batteries. Charge them only with Marport's chargers.

Warning: In case of water ingress in the product, do not charge it: battery may vent or rupture, causing product or physical damage.
Important: For Basic/Medusa chargers and Dock products with serial number before DOC2107XXX: Do not leave the sensors connected on a charger that is switched off. If the charger is not connected to the mains voltage, the sensor switches on and this will drain the battery.
Note: Avoid full discharges and charge the battery whenever possible, at any battery level. Lithium-ion batteries do not have a charge memory, so they do not need full discharge cycles.

Procedure

  1. Before charging the sensor: wash with fresh water and dry the sensor. This prevent corrosion of the charging pins.
    Note: Check that the charging pins are not damaged. If they are, contact you local Marport dealer for replacement. Below is an example of shoulder bolts damaged because of insufficient maintenance.
  2. Place the sensor and charger in a dry room like the deck or bridge. The optimal temperature while charging is between 10 and 25 °C.
  3. Place the sensor away from any installing material (e.g. wet ropes) and fix the sensor with brackets to keep it stable while charging.
  4. Allow good air circulation around the charger for cooling.
  5. Connect the 3-pin charging connector to the sensor shoulder bolts.
  6. You can apply a small film of electrical contact grease lubricant on pins.
    Tip: To maintain the electrical pins, polish them with fine sandpaper.
  7. Plug in the charger to a 115-230 Vac 50-60 Hz socket.
  8. To charge with a Dock:
    1. Make sure the Dock is connected to a power supply and turned on.
    2. Connect the charger plug to one of the 4 charging ports.
    3. Connect the 3-pin charging connector to the sensor charging pins.
      The Dock screen and Virtual Charger Room display the state of charge of the sensor.
  9. To charge with a Basic/Medusa Charger:
    1. If you have the Medusa multi-charger, turn the power switch to the ON position. The power switch lights on. If not, check the AC power cord connection.
    2. Connect the 3-pin charging connector to the sensor shoulder bolts.
    3. Look at the LED(s) on the charger box to know the charge status. For the multi-charger, there is a LED for each sensor charging cable. The charge status are:
    • Green LED: > 90 %
    • Orange LED: from 70 % to 90 %
    • Red LED: < 70 %
    Note: If the sensor is in configuration mode, it will begin to charge after 10 minutes. As long as it is in configuration mode, the charger's LED remains red, whatever the charge level.
  10. Wait for the battery to charge: standard charging cycle takes 8 to 12 hours. A fast charge configuration allows a 70 % charge in 1 hour and full charge in 4 hours.

Results

Once charged, the operational life time can be up to approximately 24 hours for a Seine Explorer and 744 hours for a Seine sensor.

The operational life time depends especially on the uplink power of the sensor, but also on the sounding range, uplink frequency and options activated.