Replacing the Pull Cords

You can replace the catch pull cords when they are worn out or damaged.

Before you begin

For this task you need the following tools:
9/64" Allen key Anti-seize

About this task

Only qualified Marport technicians can do this task.

Procedure

  1. Remove the old pull cords.
    1. Remove the four screws on the pull cord assembly with a 9/64 size Allen key.
    2. Remove the cords, spring and magnet from the hole.
  2. Install the new pull cords.
    1. Install the new pull-cord assembly on the side or on the end cap of the sensor.
    2. Apply anti-seize on the four screw threads, then tighten the screws with the 9/64 size Allen key.