Removing the Sensor from the NX Housing
Learn how to remove the sensor from the NX version of housing and how to put it back.
About
Once installed, the catch sensor housing can remain attached to the net and the sensor removed from the housing. This way, you can quickly replace discharged sensors by fully charged sensors.
Procedure
- Remove the sensor.
- Pull the locking pin to release the rod blocking the bottle, then remove the rod.
- Remove the bottle from the housing.
- After charging the sensor or completing maintenance
procedures, put it back.
- The bottle has a screw on the side of the end cap. Slide the bottle so the screw fits in the guide on the inner side of the housing.
- Pull the locking pin and slide the rod through the
housing.Note: If the pull cords are installed on the end cap: when putting back the blocking rod, make sure they are positioned so the blocking rod does not obstruct them when pulling them. It must pass above the rod.