Configuring PI Compatible Spread Sensors

You can configure Marport PI compatible spread sensors to communicate with Simrad PI receiver.

Procedure

  1. Connect the Master sensor to Mosa2.
  2. Click the tab Spread.
  3. If you have a Clump sensor, from PI Clump Channel, choose a channel for clump distance data.
  4. If you have a Clump sensor, from PI Clump Telegram, choose the update rate of clump distance data. The update of data is quicker when Fast is set, but this reduces the battery life.
    • Telegram Fast: sends data every 4 to 7 sec.
    • Telegram Normal: sends data every 13 to 16 sec.
    • Telegram Slow: sends data every 33 to 36 sec.
  5. From PI Starboard Channel, choose a channel for starboard distance data.
  6. From PI Starboard Telegram, choose the update rate of starboard distance data. The update of data is quicker when Fast is set (see above), but this reduces the battery life.
  7. If you have depth option, click the tab Depth.
  8. From Depth PI Frequency, choose a frequency for depth data.
  9. From Depth PI Telegram, choose the data update rate and range of depth.
  10. Connect to Mosa2 the Starboard sensor.
  11. Click the tab Spread.
  12. From Slave Type select Starboard Slave compatible to Marport Master.
  13. If you have depth option:
    1. From Depth > Depth PI Frequency, choose a frequency for depth data.
    2. From Depth PI Telegram, choose the data update rate and range of depth.
  14. If you have a Clump sensor, connect it to Mosa2.
  15. From Spread > Slave Type select Clump Slave compatible to Marport Master.
  16. If applicable, configure depth options as explained above.