Configuring PI Compatible Spread Sensors
You can configure Marport PI compatible spread sensors to communicate with Simrad PI receiver.
Procedure
- Connect the Master sensor to Mosa2.
-
Click the tab Spread.
- If you have a Clump sensor, from PI Clump Channel, choose a channel for clump distance data.
-
If you have a Clump sensor, from PI Clump Telegram,
choose the update rate of clump distance data. The update of data is quicker
when Fast is set, but this reduces the battery
life.
- Telegram Fast: sends data every 4 to 7 sec.
- Telegram Normal: sends data every 13 to 16 sec.
- Telegram Slow: sends data every 33 to 36 sec.
- From PI Starboard Channel, choose a channel for starboard distance data.
- From PI Starboard Telegram, choose the update rate of starboard distance data. The update of data is quicker when Fast is set (see above), but this reduces the battery life.
-
If you have depth option, click the tab Depth.
- From Depth PI Frequency, choose a frequency for depth data.
- From Depth PI Telegram, choose the data update rate and range of depth.
- Connect to Mosa2 the Starboard sensor.
-
Click the tab Spread.
- From Slave Type select Starboard Slave compatible to Marport Master.
-
If you have depth option:
- From , choose a frequency for depth data.
- From Depth PI Telegram, choose the data update rate and range of depth.
- If you have a Clump sensor, connect it to Mosa2.
- From Clump Slave compatible to Marport Master. select
- If applicable, configure depth options as explained above.