Frequency Plan

It is important to carefully plan the setup of your sensors before adding them to the system. You can create a table with a list of frequencies and complete it when you add sensors.

Boat & Channel Codes

This list shows the standard frequencies for PRP telegrams. When you configure boat codes, make sure to respect the correct interval between frequencies (see table above).

Codes
BC/CH Frequency FID (Scanmar)
C-1/CH1 42833 45
C-1/CH2 41548 32
C-1/CH3 41852 35
C-1/CH4 40810 25
C-1/CH5 42500 42
C-1/CH6 43200 49
C-2/CH1 42631 43
C-2/CH2 41417 31
C-2/CH3 41690 33
C-2/CH4 40886 26
C-2/CH5 42300 40
C-2/CH6 43100 48
C-3/CH1 42429 41
C-3/CH2 41285 30
C-3/CH3 41548 32
C-3/CH4 40970 27
C-3/CH5 42100 38
C-3/CH6 43000 47
C-4/CH1 42226 39
C-4/CH2 41852 35
C-4/CH3 41417 31
C-4/CH4 41160 29
C-4/CH5 42700 44
C-4/CH6 43300 50
C-5/CH1 42024 37
C-5/CH2 41690 33
C-5/CH3 41285 30
C-5/CH4 41060 28
C-5/CH5 42900 46
C-5/CH6 43400 51
C-6/CH1 39062 3
C-6/CH2 39375 7
C-6/CH3 39688 11
C-6/CH4 40000 15
C-6/CH5 40312 19
C-6/CH6 40625 23
C-7/CH1 38906 1
C-7/CH2 39219 5
C-7/CH3 39531 9
C-7/CH4 39844 13
C-7/CH5 40156 17
C-7/CH6 40469 21

Frequencies and intervals

The diagrams below show the bandwidth of the different types of Marport sensors and intervals you must respect when adding other sensors.

Figure 1. PRP sensors (e.g. Catch sensor, Trawl Speed, Spread sensor...)
Example: If the frequency of the sensor is 40kHz, there should be no sensors between 39.9-40kHz and 40-40.1kHz.

Figure 2. Marport Pro sensors (e.g. Trident, Door Explorer, Trawl Navigator, Speed Navigator)
Example: If the frequency of the sensor is 40kHz, there should be no sensors between 39.8-40kHz and 40-41.2kHz.
Figure 3. NBTE sensors (e.g. Speed Explorer, Trawl Explorer, Catch Explorer, Catch Navigator, Door Sounder)
Example: If the frequency of the sensor is 40kHz, there should be no sensors between 39.8-40kHz and 40-40.6kHz.

Figure 4. HDTE narrow band mode

Example: If the frequency of the sensor is 40kHz, there should be no sensors between 39.8-40kHz and 40-41kHz.

Figure 5. HDTE wide band mode
Example: If the frequency of the sensor is 40kHz, there should be no sensors between 39.8-40kHz and 40-42.6kHz.

Frequency of the sensor Bandwidth Mandatory distance with other sensors Recommended distance with other sensors

Examples of frequency allocations

  • We recommend to allocate frequencies between 34 and 56 kHz for wideband hydrophones and between 41 kHz and 44 kHz for narrowband hydrophones.
  • Echosounders are usually placed around 38 kHz, make sure to allow enough distance with them.
Example of a system with Spread, Catch, Trawl Speed sensors and Speed Explorer, Catch Explorer, HDTE and Door Sounder.
Example of a system with Spread sensors with positioning, Catch sensors, Trawl Explorer and Catch Explorer.
Example of a system for purse seining, with a Seine Explorer and depth Seine sensors.
Bandwidth

Mandatory distance with other sensors

Avoid allocating frequencies between 37 and 39 kHz because this range is generally used by echosounders.