Importing a Sensor Configuration

You can apply to a sensor a configuration that has already been made on another sensor.

Before you begin

About this task

Only the following settings are imported: trawl node, recording settings (SD card, support logs), communication options (virtual water switch, simulation mode), uplink level and frequency, echo sounder settings.

Important: If the new configuration changes the echo sounder settings, you must re-calibrate the sensor for target strength value.

Procedure

  1. Press command + A or click Menu and click User Mode > Advanced
  2. Click Menu > Import.

  3. From the window that appears, select the *.A2C or XML configuration file.

Results

The configuration is loaded into the sensor.